AK06 Compact Drive

Eine Bestellung aufgeben

Besondere Vorteile

97%

High efficiency

-20 °С ... + 60 °С (-4°F...+140°F)

Operating temperature range

20% to 36% smaller

Overall dimensions are 20% to 36% smaller than AK06 UD line

IP66/ NEMA4/ NEMA4X

Enclosure

Über das Produkt

Investment saving‡

- Universal solution for Induction and Permanent Magnet Motors - Compact overall dimensions of the AK06 CD line reduce shipping costs - AK06 CD line saves space at installation sites (offshore and onshore) - Smallest footprints to invest less in platforms and groundwork - Wide range of protocols to interface with any digital network - Junction box with terminal lugs for any type of cable connection without special tools - Sensor section does not require a separate cabinet

Maximization of Production

- Voltage Sags protection - “Catch on the fly mode” - Gas lock algorithm

Cost saving

- Efficiency 97% - low cost of ownership - Voltage Optimization Mode - Modes of automatic start - Triol Vector Control Mode

Operating in the following climatic conditions:

- Arctic - Tropical - Desert - Maritime (including offshore platforms)

Specifications



                                                

Parameters

                                                

Value


                                                

Power supply, V


                                                

3x380 ± 15% / 3x480 (-15% ... + 10%)
-50% continuously with reduced output power;
-65% up to 500 ms (with a decrease of output power)


                                                

Input frequency, Hz


                                                

50/60 (-5% ... + 5%)


                                                

Rated output current, A


                                                

100 - 3000


                                                

Overcurrent characteristics


                                                

120% of rated value for 60 sec


                                                

Output frequency


                                                

1.5 - 80 Hz, in induction motor control mode
1.5 - 200 Hz, in permanent magnet motor control mode Up to 600 Hz, in high-speed PMM control mode


                                                

Light alarm


                                                

“Work”, “Waiting”, “Stop”, “Backspin”


                                                

Operator control voltage


                                                

Option:
10 V DC, +/- 2% current not more than 30 mA,
24 V, 300 mA
110/220 V, 10A for connecting of third-party consumers


                                                

Insulation


                                                

Galvanic isolation between power and user circuits


                                                

Insulation resistance


                                                

> 5 MOhm        


                                                

Protection type


                                                

Overcurrent protection;
Power switched temperature (IGBT); Max. and min. voltage in the DC link.


                                                

Material of enclosure


                                                

Carbon steel, stainless steel


                                                

Relative humidity


                                                

100 %


                                                

Cooling type


                                                

Type of cooling air-to-air heat exchanger for cooling of power compartment, air forced to cool the winding elements of the power circuit


                                                

Number of AI


                                                

2 by default, optional extension +8


                                                

AI type               


                                                

Programmable 4..20 mA, 0..5 mA, 0..10 V (frequency reference / multifunction analog input)


                                                

Number of DIN


                                                

2 by default, optional extension +4 or more


                                                

Number of AO


                                                

Option, 4 or more programmable 4..20 mA, 0..5 mA, 0..10 V


                                                

Number of Relay Outputs


                                                

Option, 8


                                                

Communication port


                                                

Modbus


                                                

Physical interface


                                                

-2-wire RS-485/232 for Modbus by default
-Ethernet (optional) - for communication with ACS/automated control system/
-wire RS-485/232 for Modbus - for communication with a surface downhole measuring system


                                                

Frame Transmission


                                                

Modbus RTU
up to 115200 bps


                                                

DC bus Choke


                                                

Built-in


                                                

Sine filter


                                                

Built-in


                                                

Capacitor unit (for voltage sags)


                                                

Option, outdoor


        

Electrical power meter

Option, built-in
                                                

GPRS router


                                                

Option, built-in


                                                

Change of frequency task increment


                                                

0,1 Hz


                                                

Efficiency


                                                

97 % (New record)


                                                

PID mode


                                                

YES


                                                

HMI



                                                

UMKA07 controller with LCD-TFT 7 inch display, push- button control (touch screen optional);
Integration of third-party controller

    
                                                

PWM frequency


                                                

Up to 8 kHz depending on VSD type


                                                

Speed maintenance accuracy (static)


                                                

+/- 10% of rated speed in open-loop system



                                                

Control type

    
                                                

- vector control in an open-loop system without speed feedback (for PMM)

- scalar control: based on the characteristic voltage / frequency U / F (for induction motors)


                                                

Acceleration and deceleration rates


                                                

- linear, from 0.1 Hz / s;
- program mode with adjustable time of reaching given frequency