TRIOL AT24 linia LE
Złóż zamówienie Złóż zamówienieWyróżniające się korzyści
Control system
Closed loop vector control and Open loop vector control
Encoders
3 different types of encoders supported
Special algorithms
Slip compensation and anti-rollback algorithms
Motor parameters
Auto-tuning both with and without motor rotation
Remote control panel
Transient graphs
O produkcie
Safe and reliable operation
Variable Frequency Drive AT24 line LE is designed to control a synchronous and asynchronous, gear and gearless elevator winches. Triol AT24 VFD line LE is specially designed to ensure safe and reliable operation of elevator equipment and has advanced functionality for modern elevators. Programmable inputs and outputs allow configuring Triol AT24 VFD line LE to operate with any type of Variable Frequency Drive.
Unique algorithms
Triol AT24 VFD line LE is able to work with three types of encoders (incremental, absolute, sine/cosine) without the use of additional units. Unique Triol algorithms of sensor and sensorless vector control, algorithms of specialized lift functionality, slip compensation, anti-rollback algorithms are implemented in Triol AT24 VFD line LE.
Automatic measurements
Automatic measurement of motor parameters makes the setting process of Triol AT24 VFD line LE easy and precise. The function of measuring parameters without the need for motor rotation becomes indispensable when the elevator car is already mounted. Operation with UPS ensures a reliable power supply and elevator operation. Setting up and controlling Triol AT24 VFD line LE is easy due to the use of: Wi-Fi adapter with step-by-step Triol Wizard via smartphone, Service software Triol Drive for PC, Remote control panel with transient graphs
Specyfikacje
Input |
|
Input voltage, V |
3х380 / 3х480(-15 % …+10 %) |
Input frequency, Hz |
50 / 60 (-5 %…+5 %) |
Output |
|
Output current, A |
11 … 74 |
Output frequency, Hz |
0.5…400 |
Frequency resolution, Hz |
0.1 |
Acceleration / deceleration time, s |
1 …4000 |
Overcurrent characteristics |
150 % of rated value for 60 sec |
Efficiency, % |
>97 |
Motor control |
|
Control methods |
V/f (volts-per-hertz) (5 reference point) sensorless open loop vector control and sensor closed loop vector control |
PWM frequency, kHz |
2…10 |
Speed range |
1:100 in open-loop system 1:1000 in closed-loop system |
Speed accuracy (static) |
±10% of motor nominal slip in open-loop system ±0.1 % of rated speed in close-loop system |
Torque accuracy |
±10% in open-loop system ± 5 % in close-loop system |
Braking |
By frequency
Coasting Dynamic |
Acceleration / deceleration types |
S-curve, linear (3 reference points) |
Interface |
|
Terminal |
Integrated seven-segment graphic |
Light alarm |
“Ready”; “Run”; “Control channel”, “Rotation” |
Push buttons |
“Start”; “Stop”; “Fast access “ |
Control signals |
|
Customer supply |
10 V DC, up to 30 mA 24 V DC, up to 150 mA |
Number of discrete inputs |
8 |
Discrete inputs |
Programmable |
Discrete inputs type |
24 V |
Number of relay outputs |
4 |
Relay outputs type |
250 V, 1 A |
Discrete output |
2 open collector |
Number of analog inputs |
2 |
Analog inputs |
Programmable 0…10 V / 0…5 mA / 4…20 mA |
Number of analog outputs |
2 |
Analog outputs |
Programmable 0…10 V / 0…5 mA / 4…20 mA |
Communication |
|
Physical Interface |
2 wire RS-485 for Modbus |
Communication protocols |
Modbus RTU |
Frame transmission |
115200 bps by default 1200 -250000 bps |
Data format |
8 bits, 1 stop bit, no parity |
Number of addresses |
1…255 for Modbus |
Access |
Slave |
Protection |
|
Supply protections |
Phase loss, phase sequence fault |
Motor protections |
Overcurrent
Overload Underload Phase loss Current unbalance Encoder open loop Brake resistor open loop |
VFD protections |
Overload, Overheating, DC-link undervoltage, DC-link overvoltage, Power switch failure |
Insulation |
Galvanic isolation between power and user circuits |
Insulation resistance |
>1 MQ |
Configuration |
|
Braking IGBT-chopper |
Built-in |
Wi-Fi unit |
Option, built-in |
Optional equipment |
|
Remote control P24E |
Option, outdoor |
Braking resistors |
Option, outdoor |
Input line choke |
Option, outdoor |
Input EMC filter (C2) |
Option, outdoor |
Output dV/dt filter |
Option, outdoor |
Construction |
|
Enclosure |
IP21 |
Cabinet material |
Up to 7.5 kW: plastic From 11 kW: steel |
Cooling |
Forced air |
Noise level, @ 1 m, dB(A) |
<75 |
Installation |
Wall mounting |
Maintenance |
One-side |
Cable entry |
Bottom |
Operating conditions |
|
Operating conditions |
Indoor, no caustic and volatile air, no dust |
Operating temperature |
-10…+40 °C (-10…+104 F) |
Storage temperature |
-40…+50 °C (-40…+122 F) |
Relative humidity, % |
From 5 to 90 non condensing |
Altitude, m |
Up to 1000 m – rated power above 1000 m – with reduced power |
Functions
- Start/stop/ reverse of motor with set acceleration and deceleration rates
- Motor speed and torque control
- Auto-tuning of motor parameters (with rotation and without)
- 3-wire control
- Start-up torque compensation (analog input)
- Anti-rollback algorithm
- STO function
- Slip compensation
- Control of input contactor
- Control of winch brake
- 15 preset speeds for motion settings (for digital inputs)
- Automatic restart
- Encoders supported – incremental, absolute, sine/cosine
- Accelerated passing of resonant frequencies (3 ranges)
- Recording the last 32 reasons of failures