TRIOL AT24 linia SR
Złóż zamówienie Złóż zamówienieWyróżniające się korzyści
Specialized algorithms for SRP
Modular system
Build-in options
Compliance with IEEE-519 standard
IP54 (NEMA3R) IP66 (NEMA4/4X)
Enclosure
Operating temperature range
-40 °С ... + 50 °С (-40°F...+140°F)
O produkcie
System survivability algorithms:
Automatic power reduction in case of mains sag more than 15...20%; Autorestart in case of prolonged mains failure.
Equipment service algorithms:
Gearbox belt slip detection; Sensor and sensorless dynacard construction; Determining the optimum direction of rotation of the crank; Performing the balancing procedure for the SRP; Algorithm for marking rod end position; Setup macros for different SRP types; System diagnostics by dynacard; Control of motor heating by sensors or operating modes.
Automatization algorithms:
Maintaining dynamic fluid level in the well; Maintaining the maximum pump fill; Optimization of flow rate by pump filling; Maintaining the set pressure according to the sensor.
Line SR is designed to control induction motors from 7.5 to 200 kW and 380...480 V.
Specyfikacje
Input | |
---|---|
Input voltage, V | 3х380...480 (-15 % ...+10 %) |
Input frequency, Hz |
|
Output | |
Output current, A | 17.5...370 А |
Output frequency, Hz | 0...600 |
Readability frequency reference Hz | 0.1/0.01 |
Acceleration / deceleration time, s | 1...4000 |
Efficiency, % | up to 98 |
Motor control | |
Control methods |
|
PWM frequency, kHz | 1.5...10 |
Speed range | 1: 100 in open loop |
Speed accuracy (static) | ± 10% of rated motor open loop slip |
Torque accuracy | ± 10% of rated torque in open loop |
Deceleration |
|
Interface | |
HMI |
|
Light signaling | “Ready , “Run , “Fault , Heating” |
HMI VFD supports English, Spanish and one additional language of the user s choice | |
Programmable discrete inputs and outputs | |
Customer power | = 24 V, no more than 100 mA |
Number of discrete inputs | 4 |
Discrete inputs | programmable |
Discrete inputs type | 24 V |
Number of relay outputs | 2 |
Relay outputs type | 250 V, 2 A |
Number of analog inputs | 2, open collector |
1 pulse discrete input (up to 50 kHz) to connect a Hall-effect speed sensor | |
An expansion unit with 16 digital inputs and 8 relay outputs is available on request |