TRIOL AT24 line UB
Place an order 
                Distinctive benefits
Control type
Vector sensorless (open-loop) control
Motor parameters
Auto-tuning
Built-in
PID-controller
Multi-stage speed control
16 steps
4 parameter sets
Acceleration and deceleration time
About product
Simple, reliable and cost-effective solution
Variable Frequency Drive Triol AT24 line UB is a basic solution for common process tasks with simple installation, quick commissioning and easy operating. AT24 UB is simple, reliable and cost-effective solution to control pumps and HVAC systems. The integrated terminal allows making settings without additional equipment and service software.
Specifications
| Input | |
|---|---|
| Input voltage, V | 3х380 / 3×415 / 3х480 (-15 % …+10 %) | 
| Input frequency, Hz | 50 / 60 (-5 %…+5 %) | 
| Output | |
| Output current, A | 1.2 … 110 | 
| Output frequency, Hz | 0.5…400 | 
| Frequency resolution, Hz | 0.1 | 
| Acceleration / deceleration time, s | 1 …36000 | 
| Overcurrent characteristics | 120 % of rated value for 60 sec | 
| Efficiency, % | >97 | 
| Motor control | |
| Control methods | V/f (volts-per-hertz) (5 reference point) sensorless vector control (open-loop) sensor vector control (close-loop) | 
| PWM frequency, kHz | 2…10 | 
| Speed range | 1:100 in open-loop system 1:1000 in closed-loop system | 
| Speed accuracy (static) | ±10% of motor nominal slip in open-loop system ±0.1 % of rated speed in close-loop system | 
| Torque accuracy | ±10% in open-loop system ± 5 % in close-loop system | 
| Braking | By frequency Coasting Dynamic | 
| Acceleration / deceleration types | S-curve, linear (3 reference points) | 
| Interface | |
| Terminal | Integrated seven-segment | 
| Light alarm | “Ready”; “Run”; “Control channel”, “Rotation” | 
| Push buttons | “Start”; “Stop”; “Fast access “ | 
| Control signals | |
| Customer supply | 10 V DC, up to 30 mA 24 V DC, up to 150 mA | 
| Number of discrete inputs | 7 | 
| Discrete inputs | 2 Dl “Direction of rotation” by default 4 Dl programmable 1 Dl high speed pulse input | 
| Discrete inputs type | 24 V | 
| Number of relay outputs | 2 | 
| Relay outputs type | 250 V, 1 A | 
| Discrete output | 1 DO high speed or open collector | 
| Number of analog inputs | 2 | 
| Analog inputs | 1 Al 0…10 V by default 1 Al programmable 0…10 V or 0…5 mA or 4…20 mA | 
| Number of analog outputs | 2 | 
| Analog outputs | Programmable 0…10 V or 0…5 mA or 4…20 mA | 
| Communication | |
| Physical Interface | 2 wire RS-485 for Modbus | 
| Communication protocols | Modbus RTU | 
| Frame transmission | 19200 bps by default 1200, 2400, 4800, 9600,19200, 38400 bps | 
| Data format | 8 bits, 1 stop bit, no parity | 
| Number of addresses | 1…247 for Modbus | 
| Access | Slave | 
| Protection | |
| Supply protections | Phase loss | 
| Motor protections | Overload Phase loss | 
| VFD protections | Overload, Overheating, DC-link undervoltage, DC-link overvoltage, Power switch failure | 
| Insulation | Galvanic isolation between power and user circuits | 
| Insulation resistance | >1 MQ | 
| Configuration | |
| Braking IGBT-chopper | Up to 15 kw: built-in From 18 kW: option, built-in | 
| Optional equipment | |
| Braking resistors | Option, outdoor, by request | 
| Input line choke | Option, outdoor, by request | 
| Input EMC filter (C2) | Option, outdoor, by request | 
| Output dV/dt filter | Option, outdoor, by request | 
| Construction | |
| Protection degree of Enclosure | IP21 | 
| Cabinet material | Up to 7.5 kw: plastic From 11 kW: steel | 
| Cooling | Forced air | 
| Noise level, @ 1 m, dB(A) | <75 | 
| Installation | Wall mounting | 
| Maintenance | One-side | 
| Cable entry | Bottom | 
| Operating conditions | |
| Operating conditions | Indoor, no caustic and volatile air, no dust | 
| Operating temperature | -10…+40 °C (-10…+104 F) | 
| Storage temperature | -40…+50 °C (-40…+122 F) | 
| Relative humidity, % | from 5 to 90 non condensing | 
| Altitude, m | up to 1000 m – rated power above 1000 m – with reduced power | 
Functions
- Start / stop / reverse of motor with set acceleration and deceleration rates
- Auto-tuning of motor parameters
- PID-controller
- 2-wire control
- 3-wire control
- Automatic restart
- Accelerated passing of resonant frequencies (2 ranges)
- Simple PLC and multi-step speed control with 16 steps and 4 acceleration / deceleration times
- Recording the last 3 reasons of failures
 +48737866327